Cleanroom Air Filters — Pre-Filters to ULPA, EN 1822 Tested
Every stage of a cleanroom filtration system from one manufacturer: coarse and medium pre-filtration for the HVAC, carbon for gases and odors, and HEPA/ULPA terminal filters for FFUs, laminar flow and HEPA boxes.
Request pricing for:
H14 efficiency at MPPS, tested to EN 1822
From the air handler to the ceiling

Pre-filter
Washable synthetic media in aluminium frame; captures ≥5 µm to protect terminal filters. 21 or 46 mm.
AKPF21 · AKPF46
Medium panel filter
Panel filter capturing ≥1 µm for higher-efficiency pre-filtration. 21 or 46 mm.
AKMF21 · AKMF46
Medium bag filter
Pocket filter for HVAC, 3–10 pockets, 360 or 500 mm deep, large surface and low resistance.
AKBF SERIES
Activated carbon filters
Carbon panel filters and refillable assembled carbon (4 mm coal-base pellets) for TVOC, formaldehyde and odors.
AKPAF · AKCAF
V-bank filter
High-airflow V-shaped filter for variable-air-volume HVAC; glass fibre media, PU gasket, 292 mm deep.
AKVF SERIES
HEPA / ULPA filter
Glass fibre mini-pleat for FFUs, laminar flow and air showers; also with separators (150 / 292 mm) and gel seal.
AHM SERIES
PTFE & high-temperature HEPA
PTFE media with 40–50% lower resistance and chemical resistance; high-temperature HEPA for 150–350 °C depyrogenation and ovens.
AHM PTFE · AHM HT
Integrated & combined HEPA boxes
Disposable sealed HEPA boxes for tight spaces, and combined plenum-diffuser-filter boxes for ISO 5–9 ceilings.
AHM-YTH · GFUStandard HEPA and ULPA sizes (69 mm deep)
Same sizes available gel-sealed, in PTFE media, or with separators at 150 and 292 mm depth.
| Size L × W × H (mm) | Typical use | Media area | Airflow (m³/h) | H13 model · ΔP | H14 model · ΔP | U15 model · ΔP |
|---|---|---|---|---|---|---|
| 305 × 305 × 69 | Small hoods, pass boxes | 2.8 m² | 100–150 | AHM-H13-1 · 100–120 Pa | AHM-H14-1 · 120–150 Pa | AHM-U15-1 · 140–160 Pa |
| 305 × 610 × 69 | Laminar flow cabinets | 5.5 m² | 200–300 | AHM-H13-2 | AHM-H14-2 | AHM-U15-2 |
| 570 × 570 × 69 | 2×2 FFU, air showers | 9 m² | 400–500 | AHM-H13-3 | AHM-H14-3 | AHM-U15-3 |
| 610 × 610 × 69 | Ceiling modules | 11 m² | 500–600 | AHM-H13-4 | AHM-H14-4 | AHM-U15-4 |
| 1170 × 570 × 69 | 2×4 FFU (incl. FFU-900) | 20 m² | 1000–1200 | AHM-H13-5 | AHM-H14-5 | AHM-U15-5 |
Glass fibre media, water- and oil-proof · aluminium, galvanized or stainless frame · PU gasket both sides · double steel face guard · max 80 °C, 100% RH, final ΔP 500 Pa · EN 1822 tested with CE certificate. Custom sizes available.
Panel, bag and carbon filter sizes
| Size L × W (mm) | Airflow (m³/h) | Pre-filter (G) 21 / 46 mm | Medium panel (F5–F8) 21 / 46 mm | Carbon panel | Assembled carbon 292 mm |
|---|---|---|---|---|---|
| 287 × 287 | 800–900 | AKPF21-1 / AKPF46-1 | AKMF21-1 / AKMF46-1 | AKPAF21-1 (21 mm) | AKCAF-1 |
| 287 × 592 | 1600–1700 | AKPF21-2 / AKPF46-2 | AKMF21-2 / AKMF46-2 | AKPAF21-2 (21 mm) | AKCAF-2 |
| 395 × 490 | 1700–1800 | AKPF21-3 / AKPF46-3 | AKMF21-3 / AKMF46-3 | AKPAF21-3 (21 mm) | AKCAF-3 |
| 490 × 490 | 2100–2300 | AKPF21-4 / AKPF46-4 | AKMF21-4 / AKMF46-4 | AKPAF21-4 (21 mm) | AKCAF-4 |
| 490 × 592 | 2700–2800 | AKPF21-5 / AKPF46-5 | AKMF21-5 / AKMF46-5 | AKPAF21-5 (21 mm) | AKCAF-5 |
| 592 × 592 | 3200–3400 | AKPF21-6 / AKPF46-6 | AKMF21-6 / AKMF46-6 | AKPAF21-6 (21 mm) | AKCAF-6 |
Bag filters (AKBF, F5–F9): 592 × 592 or 490 × 592 face, 360 or 500 mm deep, 5–6 pockets standard, 2,600–3,400 m³/h. V-bank (AKVF, E10–E12): 592/490/287 × 592 × 292 mm, 4V.
Find the right filter.
Send the filter size, class or the equipment model — we confirm the match and quote pricing and lead time.
















