Operator working under an Airkey laminar flow hood in a pharmaceutical cleanroom
Airkey clean-air equipment

Laminar Flow Cabinets, Hoods, HEPA Boxes & Clean-Air Equipment

Create a local Class 100 (ISO 5) zone inside a lower-class room, filter supply air at the ceiling, and handle fumes without ductwork — Airkey equipment built in powder-coated or stainless steel with SS304 work surfaces.

Key fact
Class 100

Local ISO 5 work zone inside a Grade B/C room

Laminar flow

Laminar flow cabinets and hoods

Airkey horizontal laminar flow cabinets at the factory
GHCB series

Horizontal laminar flow cabinet

Horizontal HEPA airflow across an SS304 worktable; split-type optional. Noise ≤62 dB(A).

Airkey vertical laminar flow cabinet
GVCB series

Vertical laminar flow cabinet

Vertical airflow, compact structure, SS304 worktable with side glass panels; single, double or three-person.

Airkey laminar flow hood module
P28 series

Laminar flow hood (ceiling module)

Creates a partial Grade A area with vertical uniform airflow under Grade B or C — modular, easy to maintain.

ModelTypeExternal W × D × H (mm)Work zone W × D × H (mm)Air velocityMax power
GHCB-800-1Horizontal800 × 880 × 1510720 × 700 × 6000.3–0.6 m/s, adjustable300 W
GHCB-1400-1Horizontal1400 × 880 × 15101320 × 700 × 6600.3–0.6 m/s, adjustable600 W
GHCB-2000-1Horizontal2000 × 880 × 15101920 × 700 × 6600.3–0.6 m/s, adjustable900 W
GVCB-800-1Vertical · single800 × 750 × 1850720 × 710 × 6100.3–0.6 m/s, adjustable200 W
GVCB-1400-1Vertical · double1400 × 750 × 18501320 × 710 × 6100.3–0.6 m/s, adjustable200 W
GVCB-2000-1Vertical · three-person2000 × 750 × 18501920 × 710 × 6100.3–0.6 m/s, adjustable400 W
P28-CL01-00Laminar flow hood · 1 HEPA1000 × 800 × 650—0.45 m/s ±15%, adjustable220 V / 50 Hz
P28-CL02-00Laminar flow hood · 2 HEPA2000 × 800 × 650—0.45 m/s ±15%, adjustable220 V / 50 Hz

All Class 100 (FS 209E). Laminar flow hoods: 60–65 dB(A), ≥300 lux, SUS304 or SUS316. Laminar flow cabinets are product-protection equipment, not biological safety cabinets — for hazardous drugs see containment and BSCs.

Terminal filtration

HEPA boxes (GFU series)

Compact terminal filter boxes for cleanroom ceilings — plenum, diffuser and HEPA filter in one, ducted from the top or side, with DOP test ports and room-side filter replacement. For ISO 5–9 rooms. Height 542–590 mm, 24–72 kg, powder-coated or stainless, EN 1822-tested filters H13–U17.

ModelAirflow (m³/h)Size L × W (mm)Ceiling cut-out (mm)
GFU-5500370 × 370380 × 380
GFU-101000534 × 534 · 660 × 660545 × 545 · 670 × 670
GFU-151500776 × 534 · 680 × 680 · 965 × 660786 × 545 · 690 × 690 · 975 × 670
GFU-2020001018 × 534 · 1270 × 6601030 × 545 · 1280 × 670
GFU-222200995 × 6801005 × 690
GFU-3030001310 × 6801325 × 690
More clean-air equipment

Purifiers, fume hoods, assembly lines and gowning

Airkey air purifier
AK-600 · AK-1200

Air purifier

HEPA 99.995% @ 0.3 µm, <50 dB, LED screen, adjustable velocity. Ceiling-mounted or mobile. 1P/220 V.

Airkey ductless fume hood
BAT series

Ductless fume hood

No ductwork: carbon + HEPA + pre-filters handle organic and inorganic gases, formaldehyde and ammonia to below 1% of TWA. 800–1800 mm wide, 0.4–0.6 m/s face velocity, <56–60 dB(A).

Airkey clean assembly line
CPB-AS-1400A

Clean assembly line

HEPA module over an anti-static PVC belt conveyor creates Class 100–100K zones along the line; aluminium alloy frame, 450–1200 lux, custom lengths.

Airkey clean wardrobe for cleanroom garments
Wardrobe · GGS-A tunnel

Clean wardrobe & air shower tunnel

HEPA-ventilated wardrobe keeps gowns clean (Class 100). The GGS-A tunnel purifies items in transit at 15–20 m/s with 18 nozzles.

Ductless fume hood

BAT series specifications

ModelExternal W × D × H (mm)Internal W × D × H (mm)Air treatmentCarbon / HEPA filtersPowerWeight
BAT-800814 × 630 × 1091–1211800 × 560 × 760220 m³/h2 / 1130 W90 kg
BAT-10001014 × 630 × 1091–12111000 × 560 × 760220 m³/h2 / 1135 W110 kg
BAT-13001314 × 630 × 1091–12111300 × 560 × 760220 m³/h2 / 1145 W130 kg
BAT-16001614 × 630 × 1091–12111600 × 560 × 760440 m³/h4 / 2220 W180 kg
BAT-1000S1014 × 750 × 1131–12511000 × 700 × 800440 m³/h4 / 2225 W110 kg
BAT-1300S1314 × 750 × 1131–12511300 × 700 × 800440 m³/h4 / 2300 W140 kg
BAT-1600S1614 × 750 × 1131–12511600 × 700 × 800660 m³/h6 / 3320 W180 kg
BAT-1800S1814 × 750 × 1131–12511800 × 700 × 800880 m³/h8 / 4400 W210 kg

Options: filter-saturation monitoring, room TVOC monitoring, remote monitoring. 220 VAC ±10%, 50 Hz as catalogued — 60 Hz US supply confirmed with your quote.

Add an ISO 5 zone or clean-air equipment.

Tell us the process, room class and space — we’ll recommend the cabinet, hood or HEPA layout.